Biopac Science Lab Line In Ports
The Biopac Science Lab MP40 unit connects to the computer via Line-In. Important—Audio line-in is not the same as headphones. Typical audio line-in connectors are shown below for Windows and…
Read moreLoading
The Biopac Science Lab MP40 unit connects to the computer via Line-In. Important—Audio line-in is not the same as headphones. Typical audio line-in connectors are shown below for Windows and…
Read moreSALT CONTENT Disposable Electrode Chloride % EL500 10% EL501 10% EL502 4% (solid gel) EL503 7% EL504 4% (solid gel) EL507 0.5% EL508 10% EL509 n/a: dry electrode—use your own…
Read moreIt is possible to validate the signals coming from any DA100A/B/ or C amplifier by using a CBLCAL* Calibration Cable. The cable connects to the front of the amplifier and…
Read moreIt is possible to validate the signals coming from any BIOPAC biopotential amplifier* by using a CBLCALC Calibration Cable. The cable connects to the front of the amplifier and the…
Read moreIf the signal from the amplifier is not on zero, it is possible to remove the offset by using the Zero Adj screw at the top of the amplifier. Make…
Read moreUse the CBL201 to convert older amplifiers that use 2 mm pin sockets to the newer 1.5 mm touchproof connectors. This is useful if you have an older amplifier with…
Read moreBIOPAC Research Systems were updated from MP150/UIM to MP150/HLT in August 2016 Sophisticated solutions for data acquisition and analysis Each MP System (MP100 or MP150) is a complete and expandable…
Read moreHere are some suggestions for overcoming the problem of stimulation artifact when applying a stimulation voltage to a muscle. Have the ground between the stimulating electrodes and the recording…
Read moreTo duplicate a waveform, select the waveform (channel) and click “Edit > Duplicate Waveform”. For Windows versions of AcqKnowledge older than version 4.0: When selecting the waveform, BIOPAC recommends choosing…
Read moreThe “Electrode Check” port on the front panel of MP36 and MP35 units is dseigned to measure impedance. As a rule of thumb, impedance levels below 10 kOhms are ideal,…
Read moreClipping If the Biopac Science Lab system check generates a prompt that the MP40 is clipping, click Check System and try to run the system check again. Repeat if necessary.…
Read moreIf you want to use a fixed IP address when connecting directly with the MP150 system via a crossover cable and using the UDP protocol, you should use the following address…
Read more