Description
The Dual Wireless EGG BioNomadix Transmitter is a module specifically designed to measure Electrogastrogram (EGG) data—the peristaltic, wavelike contractions of the stomach—on one or both channels. Using AcqKnowledge, wide bandwidth EGG data can be filtered to lower values to accommodate closer inspection of specific EGG frequencies, such as Bradygastria, Normogastria and Tachygastria or identification of ECA and ERA. To extract a bipolar measurement between two unipolar measurements referenced to a common abdominal electrode site, use the equation generator in AcqKnowledge.
EGG signal data is transmitted at a rate of 2,000 Hz, providing an extremely high resolution EGG waveform at the receiver’s output. Raw data from the pair is bandlimited from 0.005 Hz to 1.0 Hz, to provide a very high quality recording. The matched pair incorporates internal highpass and lowpass filters to provide for high quality amplification of the EGG waveform with associated Electrical Control Activity (ECA) and Electrical Response Activity (ERA). The high signal to noise ratio and high time-based sampling resolution permit the pair to be used for specific gastric slow wave propagation measurements, gastrointestinal motility analysis, peristaltic propagation studies or migrating myoelectric complex evaluation.
Use with a BioNomadix Logger or matched Receiver.

Cloth Base Electrodes
Micro Electrode Amplifier
Disposable Mouthpiece
Animal Pneumotachs 17 ml/sec-1.7 L/sec
Disposable Facemask
Interface Low Z Strain Gauge
Soft Dry Electrode | Ear
Goniometers & Torsiometers - MP3X/45/46
EDA Analysis Software Module
Ag-AgCl Electrodes
Wireless Temperature Transducers - BioNomadix
EDA Electrodermal Activity Amplifier
NIBP Finger Cuff Sensors
Micropressure Sensors
EDA Electrodermal Activity Amplifier for MRI
O-ring kit for NIBP100D or NIBP100E
Fiber Optic Temperature System
Blood Pressure Tail Cuffs
Programmable Stimulation System for E-Prime
Custom Input/Output
AcqKnowledge License Pack: Scripting, NDT, BHAPI, ACKAPI
Heated Flow Heads
Interface Narco (7 pin)
Noninvasive Cardiac Output Module
Autoclavable Mouthpiece
Electrobioimpedance Amplifier
Interface Beckman (12 pin)
fNIRS Headband
Goniometers & Torsiometers
Differential Pressure Transducers
Laser Doppler Single Fiber Probes
Custom Transducer Interface
Tail Cuff Sensor for MRI
Reusable Mouthpiece
Pressure Pad / Respiration Xdr - MP3X/45
Disp. Radiotranslucent Electrode, 100/pk
BioNomadix 2Ch Wireless SKT Transmitter
Interface Hugo Sachs/Harvard Apparat
Tubing - Smooth Bore
Gold-plated Cup Electrodes
Respiratory Effort Trans, TP
Pulse Oximetry Transducers
Couplers
Electrogastrogram Amplifier 
